Gold Member Since 2006
Audited Supplier
LONGFIAN SCITECH CO., LTD.

Medical Infusion Pump, Ce Infusion Pump, Syringe Infusion Pump manufacturer / supplier in China, offering Double Channels Syringe Pump (JAZ-1800D), Low Noise Light Weight Medical Use and Houme Use 5L Oxygen Concentrator, 5liter Everflo Qualtiy Oxygen Concentrator and so on.

(/ )

Supplier Homepage Product Infusion Pump,syringe pump,Drip Controller Double Channels Syringe Pump (JAZ-1800D)

Double Channels Syringe Pump (JAZ-1800D)

FOB Price: Get Latest Price
Min. Order: 1 Piece
Production Capacity: 500 PCS/Week
Transport Package: Carton
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: JAZ-1800D
  • Material: Metal
  • Application: Medical
  • Group: Adult
  • Syringe Use: Intramuscular Injection
  • Medical Device Regulatory Type: Type 2
  • Flow Rate(Rate Mode): 0.1-800.0 Ml / Hr (0.1 Ml / Hr Step)
  • Power Supply: AC100~240V, 50/60Hz, Internal Lithium-
  • Bolus Volume: 1.0 -100ml, 0.1ml Step
  • Specification: CE & ISO
  • HS Code: 90183900
  • Type: Syringe
  • Volume: 20ml
  • Certification: CE, ISO13485
  • Needle: Without Needle
  • Disinfection: Without Disinfection
  • Medical Devices Reg./Record No.: Jsyjxzz20132540059
  • Purge Rate(Ml/H): 800ml/H
  • Volume Limit Range: 0-1999.9ml, 0.1ml Step
  • Trademark: Longfian
  • Origin: China
Product Description
Features

Compatible with syringes of most of the standard brands.
Automatic Calibration for syringes.
Three working modes: Rate control mode, Time control mode and Dose weight control mode (ug/kg/min or mg/kg/h).
Built in rechargeable battery (Lithium-ion polymer battery).
Alarm functions: Occlusion, empty, near empty, low battery, infusion over, syringe loose, etc
Three levels of the occlusion limited pressure: High, middle and low.
Three levels of alarm sound: High, middle and low.
The Syringe pump goes into KVO mode automatically as infusion is completed.
Purge / Bolus function.

Technical Specification

1. Flow range (Rate mode):
50 ml syringe: 0.1 1800.0 ml / hr (0.1 ml / hr step)
20 ml syringe: 0.1 800.0 ml / hr (0.1 ml / hr step)
10 ml syringe: 0.1 400.0 ml / hr (0.1 ml / hr step)
2. Accuracy: +/- 2% (After correct calibration)

3. Time setting mode range:
Volume: 0.1 199.9ml, 0.1ml step
Time: 1 1999min, 1min step
4. Weight setting mode range:
Sol. Volume: 0.1 199.9ml, 0.1ml step
Drug mass: 0.1 999.9ml, 0.1 ml step
Dose: 0.01 99.99ug/kg/min, 0.01ug/kg/min step
0.01 99.99mg/kg/h, 0.01mg/kg/h step
Weight: 0.1 99.9kg, 0.1kg step
100 300kg, 1kg step

5. Purge rate:
1800ml/h (50ml), 800ml/h (20ml), 400ml/h (10ml)
6. Volume limits range: 0 1999.9ml, 0.1ml step
7. Bolus volume: 1.0 100ml, 0.1ml step

8. Bolus Rate:
10ml syringes: 1.0 400.0ml/hr, 0.1ml/hr step
20ml syringes: 1.0 800.0ml/hr, 0.1ml/hr step
50ml syringes: 1.0 1800.0 ml/hr, 0.1ml/hr step
9. Spec of the fuse: F1AL /250V, two (inside)
10. Power supply: AC100~240V, 50/60Hz, Internal Lithium-ion polymer battery: DC 11.1V, ≥ 1600mAh. The battery backup is approx. 8 hours (when using a fully charged battery and running at 5 ml/h).

11. Power consumption: ≤ 25VA
12. Class: I
13. Type: CF
14. Size: 280mm x 160mm x 130mm
15. Net Weight: 3.5 Kg. (Approx)

16. Operating condition:
Ambient temperature: 10-40degree C
Relative humidity: 20-90%
17. Storage condition:
Ambient temperature: -10~55degree C
Relative humidity: 10~90%.
18. Possibility of creation of a database about used solutions (drugs)